Three windows, one office building

Keep the window
The glass in the building today. Everything else is measured against it.
Add a secondary window
A secondary window set inside or outside the existing one, with an air gap between 25 and 89 mm.
Replace to code
A whole new window at code level: U 2.04 W/m²K, SHGC 0.38, VT 0.60.

How it works

The answers come from machine-learning models trained on EnergyPlus simulations, so a result arrives in a second instead of after a simulation run.

  1. 1

    Describe the building

    A 3 to 12 story medium office in Denver. Set wall direction, window-to-wall ratio, heating and cooling setpoints and the lowest indoor humidity.

  2. 2

    Choose the glass

    Select the existing window and the secondary window from 115 products by Alpen, Cardinal, Guardian, Pilkington, Viracon and Vitro.

  3. 3

    Read the comparison

    Site energy, heating, cooling, uncomfortable hours, condensation on each side of the building, installed cost and simple payback.

What it covers, and what it does not

The models were trained inside these limits, so the calculator refuses values outside them. Other building types, other cities and other climates are not covered. Cost figures are demo-level estimates, and payback is a range, not a promise.

Try it with your building
Building
Medium office, 3 to 12 stories
Place
Denver, Colorado, climate zone 5B
Window-to-wall ratio
0.20 to 0.50
Heating setpoint
20 to 23 °C
Cooling setpoint
24 to 27 °C
Minimum indoor humidity
20 to 40 %