Three windows, one office building
- Keep the window
- The glass in the building today. Everything else is measured against it.
- Add a secondary window
- A secondary window set inside or outside the existing one, with an air gap between 25 and 89 mm.
- Replace to code
- A whole new window at code level: U 2.04 W/m²K, SHGC 0.38, VT 0.60.
How it works
The answers come from machine-learning models trained on EnergyPlus simulations, so a result arrives in a second instead of after a simulation run.
- 1
Describe the building
A 3 to 12 story medium office in Denver. Set wall direction, window-to-wall ratio, heating and cooling setpoints and the lowest indoor humidity.
- 2
Choose the glass
Select the existing window and the secondary window from 115 products by Alpen, Cardinal, Guardian, Pilkington, Viracon and Vitro.
- 3
Read the comparison
Site energy, heating, cooling, uncomfortable hours, condensation on each side of the building, installed cost and simple payback.
What it covers, and what it does not
The models were trained inside these limits, so the calculator refuses values outside them. Other building types, other cities and other climates are not covered. Cost figures are demo-level estimates, and payback is a range, not a promise.
Try it with your building- Building
- Medium office, 3 to 12 stories
- Place
- Denver, Colorado, climate zone 5B
- Window-to-wall ratio
- 0.20 to 0.50
- Heating setpoint
- 20 to 23 °C
- Cooling setpoint
- 24 to 27 °C
- Minimum indoor humidity
- 20 to 40 %